E-mail: sales001@bosschemical.com                                              JINAN BOSS CHEM CO.,LTD
Telephone: +86-15628782329
You are here: Home » Products » 98% reagent grade 1,3,6,8-PYRENETETRASULFONIC ACID TETRASODIUM SALT Cas 59572-10-0 PTSA

loading

Share to:
facebook sharing button
wechat sharing button
linkedin sharing button
whatsapp sharing button
sharethis sharing button

98% reagent grade 1,3,6,8-PYRENETETRASULFONIC ACID TETRASODIUM SALT Cas 59572-10-0 PTSA

Synonyms:1,3,6,8-Pyrenetetrasulfonic acid tetrasodium salt
1,3,6,8-Pyrenetetrasulfonic acid sodium salt
1,3,6,8-Pyrenetetrasulfonate tetrasodium salt
Pyrene-1,3,6,8-tetrasulfonic acid tetrasodium salt
Tetrasodium pyrene-1,3,6,8-tetrasulfonate
Tetrasodium pyrene tetrasulfonate
Formula:C₁₆H₆Na₄O₁₂S₄
Weight:610.43
HS Code:2904100000
Grade:≥98% reagent grade
Hazard Class:General Chemical
Availability:
  • 59572-10-0

  • bosschemical

  • 59572-10-0

what is 1,3,6,8-PYRENETETTRASULFONIC ACID TETRASODIUM SALT cas59572-10-0 used for?

1,3,6,8-Pyrenetetrasulfonic acid tetrasodium salt (PTSA, CAS No. 59572-10-0, EC No. 261-794-7 in industrial water treatment and fine chemical industries) is an anionic polysulfonate fluorescent tracer with excellent water solubility, extremely high fluorescence quantum yield, and outstanding chemical stability. It typically appears as a yellow to yellowish-green crystalline powder and exhibits strong blue fluorescence in aqueous solution.

1. 1,3,6,8-PYRENETETRASULFONIC ACID TETRASODIUM SALT (CAS 59572-10-0) Basic Chemical Properties

English name : 1,3,6,8-Pyrenetetrasulfonic acid tetrasodium salt

Aliases: Pyrenetetrasulfonic acid tetrasodium salt, PTSA, 1,3,6,8-pyrenetetrasulfonic acid tetrasodium salt, pyrene-1,3,6,8-tetrasulfonic acid tetrasodium salt

Abbreviation: PTSA

CAS: 59572-10-0

EC: 261-794-7

Molecular formula and molecular weight : C16H6Na4O12S4 , molecular weight is 610.43 g/mol

Physical appearance: Yellow to yellowish-green crystalline powder

Main physicochemical parameters:

Melting point: > 300°C (high thermal stability)

Excitation wavelength : Approximately 365 nm - 375 nm (long-wave ultraviolet region)

Emission wavelength ( ): Approximately 400 nm - 405 nm (strong blue light region)

Fluorescence quantum yield: close to 1.0 (precisely detectable at extremely low ppb levels)

Solubility: Very soluble in water, slightly soluble in polar organic solvents such as methanol and ethanol, and insoluble in non-polar organic solvents.

Core chemical and physical properties:

High fluorescence sensitivity and optical stability: The molecular structure contains a large conjugated pyrene ring and four highly polar sodium sulfonate groups, which have an extremely strong absorption cross section and strong blue fluorescence. The fluorescence signal is not easily photobleached.

Excellent chemical and thermal stability: It remains highly stable in a wide pH range (pH 2-12), high temperature, high pressure and water systems containing strong oxidizing bactericides (such as chlorine, sodium hypochlorite, chlorine dioxide), and does not participate in the chemical reaction of water treatment agents.

Extremely low physical adsorption and excellent water miscibility: The strong electronegativity of sulfonate makes it extremely difficult for it to be adsorbed by pipe walls, heat exchanger surfaces, suspended solids or biological slime, ensuring that the tracer concentration and the actual water quality reagent concentration maintain a strict linear ratio.


Applications and uses of tetrasodium 1,3,6,8-pyrenetetrasulfonic acid (PTSA / CAS 59572-10-0)


1. Online fluorescence tracing and automatic dosing control for industrial circulating cooling water systems

Online real-time monitoring of water treatment agent concentration (Fluorescent Tracing): PTSA is premixed into corrosion and scale inhibitors (such as polyacrylic acid and organophosphonates) at a fixed ratio. By detecting the fluorescence intensity of PTSA in the circulating water in real time using a fluorescence sensor, the actual effective concentration of the water treatment agent can be accurately calculated, avoiding insufficient dosage leading to scaling or excessive dosage causing waste.

Automatic dosing control system for circulating water system (PID linkage): In conjunction with an online fluorescence detector and PLC control system, it realizes fully automated quantitative dosing based on the evaporation concentration ratio and sewage discharge of circulating water, thereby improving heat exchange efficiency and system operation stability.

2. Tracing and Leak Detection of Reverse Osmosis (RO) and Nanofiltration (NF) Membrane Water Treatment Systems

Monitoring of reagent addition in membrane separation process: In reverse osmosis membrane systems for seawater desalination, brackish water desalination, and industrial pure water production, it is used as a quantitative tracer for reverse osmosis antiscalant to ensure accurate addition of antiscalant before membrane.

Diagnosis of physical defects and leaks in membrane modules: Utilizing the low adsorption of PTSA to membrane materials and its high fluorescence detection sensitivity, PTSA is injected into the system as an indicator to quickly locate the cross-contamination location caused by membrane fiber breakage, O-ring damage, or spiral wound membrane breakage.

3. Monitoring of medium and low pressure boiler water treatment, HVAC and closed-loop circulating water systems.

Tracing of thermal boilers and district heating systems: Monitoring the reagent residence time (RTD) and makeup water rate in boiler feedwater and closed-loop circulating water systems to assess the risk of scaling and corrosion within the system.

Leak location for ground source heat pump and central air conditioning chilled water systems: used for locating hidden leaks in the water pipe network of large air conditioning water systems.

4. Laboratory fluorescence analysis, ultrasensitive spectral detection and calibration standards

Calibration Reference for Fluorescence Spectrophotometers and Sensors PTSA is widely used as the standard calibration material for fluorescence spectrometers, online fluorescence detectors and fluorescence water quality analyzers, because of its extremely high fluorescence quantum yield and extremely stable spectral characteristics.

Fluid dynamics and microfluidic chips Research Tracing: Using fluorescent tracers to observe flow paths and mixing efficiency of aqueous fluids in microfluidic systems and fluid dynamics laboratories.

5. Water systems and auxiliaries in textile printing and dyeing, and papermaking industries.

Monitoring of wastewater diversion and wet-end auxiliaries in dyeing and printing Used in papermaking industry wet-end coating and dyeing and printing auxiliaries formulation, used to monitor the retention rate and dispersion uniformity of functional polymeric auxiliaries in pulp fibers.

Industrial wastewater pipeline flow tracking: for tracking the hidden direction of wastewater diversion pipeline of factories, investigating illegal cross-discharge.

6. Water-oil interface detection, formation tracing, and oilfield chemical auxiliary applications

Water injection systems and tracers for water drive in oil fields: In tertiary oil recovery (EOR), water is injected into the oil reservoir as a water phase tracer to determine the porosity of the reservoir, preferential flow channels of water, and the connectivity between the injection and production wells.

7. Optoelectronic materials, special water-based coatings and anti-counterfeiting ink additives

Invisible fluorescent anti-counterfeiting ink and secure printing: Utilizing its property of emitting bright blue light under long-wave ultraviolet light excitation, water-based invisible anti-counterfeiting ink is formulated for use in printing invoices, special packaging, and anti-counterfeiting labels.

Waterborne coatings and adhesives curing uniformity testing: Used as a fluorescent indicator component in special waterborne industrial coatings to test coating thickness and coverage uniformity.


Summary


1,3,6,8-Pyrenetetrasulfonic acid tetrasodium salt (CAS 59572-10-0, EC 261-794-7), with its extremely high fluorescence quantum yield, excellent stability under strong oxidation and high temperature and pressure environments, extremely low physical adsorption properties, and irreplaceable role in automated dosing of industrial circulating water, reverse osmosis membrane leak diagnosis, spectral calibration standards, and oilfield formation tracing, has comprehensively transformed from a basic fluorescent dye into an indispensable high-efficiency and multifunctional cornerstone chemical in modern industrial and scientific research testing fields worldwide, including online fluorescent tracers for industrial water treatment, scale inhibitors for reverse osmosis membranes, high-precision fluorescence analysis calibration standards, and special anti-counterfeiting technologies.


Previous: 
Next: 
Product Inquiry

Why choose us?

01
Source manufacturer, price advantage​​​​​​​
Experience in producing and exporting 500+ chemicals, factory direct supply​​​​​​​
02
Extensive export experience​​​​​​​
Exporting to over 70 countries including the USA, Canada, UK, Australia, Japan, South Korea, Southeast Asia, and Brazil
03
Flexible minimum order quantity​​​​​​​
No quantity limit for samples and small trial orders, test first, then place an order
04
Fast response​​​​​​​
24-hour online sales staff to reply to inquiries
05
Established logistics​​​​​​​
Professional freight forwarder for chemicals, export packaging​​​​​​​
06
Controllable quality​​​​​​​
Each batch comes with TDS/MSDS/COA; accepts third-party testing (SGS, etc.)

Chemical detection methods

  • Spectroscopic Analysis Methods

    Ultraviolet-Vis Spectrophotometry (UV-Vis)
    Infrared Spectroscopy (IR/FTIR)
    Atomic Absorption Spectroscopy (AAS)
    X-ray Fluorescence Spectroscopy (XRF)
    Nuclear Magnetic Resonance Spectroscopy (NMR)

  • Chromatographic Analysis

    Gas Chromatography (GC)
    High Performance Liquid Chromatography (HPLC)
    Ion Chromatography (IC)
    Thin Layer Chromatography (TLC)

  • Mass Spectrometry Analysis

    GC-MS / LC-MS/MS: Qualitative and Quantitative Analysis
    ICP-MS: Trace Metal Elements (ppb Level)
    TOF-MS: Precise Molecular Weight Determination

  • Electrochemical analysis methods
    Polypotentiometric methods
    Conductivity methods
    Polarographic methods / Voltammetric methods
    Coulometric analysis
  • Thermal Analysis Methods
    Thermogravimetric Analysis (TGA)
    Differential Scanning Calorimetry (DSC)
    Differential Thermal Analysis (DTA)
  • Classical wet chemical analysis
    Titration analysis
    Gravity analysis
ABOUT COMPANY
Founded in 2010, JINAN BOSS CHEM CO.,LTD. is a large-scale hi-tech enterprise focused on the research and development of fine chemicals and international trade.​​​​​​​
CONTACT INFO
Do you want to become our customer?
Quick Request​​​​​​​


Copryright JINAN BOSS CHEM CO.,LTD Support By Leadong/ Privacy Policy